Table of contents

General Maintenance Checklist Section Item to inspect 1. Developer material 2. Doctor blade 3. Developer unit drum seal 4. Oil seal portion 6. Drum cleaning blade 7. Recovery blade Processing 8. Felt seals on both ends unit EPU of the cleaning blade 9.

E Studio 282 Driver Windows 7

Main charger case related parts Discharge LED Wire cleaning pad Main charger wire Main charger grid Main charger contact Drum Drum shaft Drum thermistor Toner recovery auger drive Toner cartridge drive gear Around EPU area Fuser belt Upper heat roller Fuser roller Fuser unit Lower heat roller Belt guide Separation guide Separation fingers Fuser unit Lower thermistors Fuser inlet guide Fuser exit guide Paper exit roller Image quality Image quality sensors area control Color registration Laser unit Slit glass Pick-up roller Feed roller Separation roller Bypass pick-up roller Paper feeding Bypass feed roller system Bypass separation roller Registration roller Paper guide Paper dust removal brush Drive gears tooth face Registration unit support bushings Original glass Platen cover Mirror-1 Mirror-2 Mirror-3 Scanner Reflector Lens Exposure lamp Original-width indicator Automatic original detection unit Slide sheet Air filter Transfer roller Y, M, C, K Drive roller cleaning felt Transfer belt cleaning blade Transfer belt recovery blade Transfer belt drive roller Transfer belt driven roller Color registration sensor.

Color Maintenance Checklist Section Item to inspect 1. Developer material Y,M,C 2. Discharge lamp Drum thermistor Y Toner recovery auger drive Image quality Move the developer removal shutter lever in the direction of the arrow shown to close the developer removal opening.

Remove the developer unit cover. Insert the doctor blade cleaning jig between the doctor blade and the sleeve and move the jig back and forth along the edge 3 times to clean the doctor blade. After the cleaning, return the developer removal shutter lever to open the developer removal opening move the lever in a direction reverse to 1.

Making the developer removal opening point downward, remove the developer material remaining in the developer unit. Shake the developer unit to the right and left, and rotate the mixer and the sleeve alternately. Developer material. The same presedure as 1 : Move the developer removal shutter lever in the direction of the arrow shown in figure to close the developer removal opening.

Cleaning blade If poor cleaning has occurred due to such causes as adhesion of paper dust, etc. Recovery blade If the blade edge has been marred, replace the blade regardless of the number of printouts that have been made so far. Ozone filter If the ozone filter is heavily dirty, replace it.


  • E Studio Driver Windows 7.
  • Asus F9e Camera Driver?
  • Toshiba e-STUDIO C - multifunction printer - color Specs - CNET.
  • video cutter mac os x.
  • Configuring The Printer On Mac Os X - Toshiba E-STUDIO C Printing Manual [Page ].
  • list of online rpg games for mac?

Main charger case and charger wire To clean the inside of the main charger case and the charger wire, use a cloth which should be soaked in water and then wrung lightly. Developer unit and cleaner unit Check if the outside surfaces including the bottom surfaces are dirty, and clean if necessary. Developer material When the developer material is replaced, be sure to perform "automatic adjustment of the autotoner sensor" adjustment mode , , Drum seal Use a cloth which should be soaked in water and then wrung strongly to clean the front seal.

If toner is fused tightly on the tip, the tip may be damaged if you try to scrape the toner off forcefully. So, replace it that is heavily dirty with toner. Don't touch the sensor head inside the shutter. Developer material M 1. Developer material C 1. Developer material K Doctor blade cleaning jig 6. Charger wire cleaning pad Ozone filter Separation finger Oil roller Cleaning roller Transfer roller Toner and developer Toner and developer should be stored in a shaded place where the ambient temperature is between 10 to 35C no condensation , and should also be protected against direct sunlight during transportation.

Photoconductive drum Like toner and developer, Photoconductive drums should be stored in a dark place where the ambient temperature is between 10 to 35C no condensation. They should also be stored horizontally on a flat surface.

Toshiba Copier - Printer Configuration - IT Frequently Asked Questions (FAQ) - Berkeley Lab Commons

Copy paper Avoid storing copy paper in places where it may be subjected to high humidity. After a package is opened, be sure to place and store it in a storage bag. So, do not touch the drum surface with your bare hands. When the drum is replaced with a new one, be sure to apply patting powder lubricant to the entire surface of the new drum before installing.

Application of the patting powder is for reducing the friction between the drum and the cleaning blade. If the application of patting powder is neglected, the drum and the cleaning blade may be damaged. When some fibers adhere to the cleaning blade edge, they may reduce the cleaning efficiency and, in addition, may damage the blade and the drum.

Setting Up Teacher Laptops to Toshiba Copier (MAC only)

Be sure to remove any fibers found adhering to the blade. Otherwise, the drum will be fatigued, producing some background fogging on the image after being installed in the copier. However, this effect will decrease as time elapses. Use sufficiently thick cleaning cotton so as not to touch the drum surface inadvertently with your fingertips or nails. Also, remove your rings and wristwatch before starting cleaning work to prevent accidental damage to the drum.

Do not use organic solvents such as alcohol or silicone oil as they will have an adverse effect on the drum. Never use selenium refresher, either. So, replace the drum with a new one. Do not rub the edge with a cloth or soft pad.

Video of the Day

Do not stain the edge with any oil or fingerprints, etc. Do not allow solvents such as paint thinner to touch the blade. Do not leave any lint or dirt on the blade edge. Do not place the blade near a heat source. Prevent oil or other foreign matter from staining the belt surface. Do not allow alcohol or any other organic solvent to come into contact with the transfer belt.


  • Related titles.
  • Toshiba Copier - Printer Configuration - IT Frequently Asked Questions (FAQ) - Berkeley Lab Commons!
  • mp3 to midi online converter mac;
  • Toshiba E-Studioc c c Service Handbook | Image Scanner | Microsoft Windows?
  • Why is the built-in webcam not detected - TechSpot Forums;
  • Toshiba E Studio Twain Driver 1.0.

Do not apply external pressure that might scratch the transfer belt. Be careful not to leave any scratch or dent on the roller surface. Do not touch the belt surface with your bare hands. Do not allow alcohol or any other organic solvent to come into contact with the fuser belt. Do not apply external pressure that might scratch the fuser belt.

Search by Model

Lower heat roller Do not leave any oil fingerprints, etc. Be careful not to allow any hard object to hit or rub against the lower heat roller, or it may be damaged, possibly resulting in poor cleaning. Clean the separation guide and fingers and check for chipped tips. Check the cleaning effect of the cleaning roller.

Check the thermistors for proper contact with the upper and lower heat rollers. Check the fused and fixed condition of the toner. Check the gap between the inlet guide and lower heat roller. Check the fuser belt for proper transportation. Check the lower heat roller for proper rotation. If this happens, wipe the surface clean with a suitable cloth. For easier cleaning, clean the belt and roller while they are still warm.